Sun SPARCstation Ultra-1 Server


Offerta di partenza

200.00


Consegna

Ritiro da parte dell'acquirente a , CHF 0.00
Venditore

96.4%

Marca

Sun

Condizioni

Usato


Verkleidung des Gehäuses an der Vorderseite beschädigt. Die Maschine ist ansonsten aber in Ordnung und funktionsfähig. Solaris 2.9 bootet.

....

Setting diag-switch? NVRAM parameter to true

Probing Memory Bank #0 32 + 32 : 64 Megabytes

Probing Memory Bank #1 0 + 0 : 0 Megabytes

Probing Memory Bank #2 128 + 128 : 256 Megabytes

Probing Memory Bank #3 0 + 0 : 0 Megabytes

Probing UPA Slot at 1e,0 Nothing there

Probing /sbus@1f,0 at e,0 SUNW,fas sd st SUNW,hme SUNW,bpp

Probing /sbus@1f,0 at 0,0 cgsix

Probing /sbus@1f,0 at 1,0 SUNW,qfe SUNW,qfe SUNW,qfe SUNW,qfe

SC Control: EWP:0 IAP:0 FATAL:0 WAKEUP:0 BXIR:0 BPOR:0 SXIR:0 SPOR:1 POR:0

Incorrect configuration checksum;

Setting NVRAM parameters to default values.

Setting diag-switch? NVRAM parameter to true

Probing Memory Bank #0 32 + 32 : 64 Megabytes

Probing Memory Bank #1 0 + 0 : 0 Megabytes

Probing Memory Bank #2 128 + 128 : 256 Megabytes

Probing Memory Bank #3 0 + 0 : 0 Megabytes

Probing UPA Slot at 1e,0 Nothing there

Probing /sbus@1f,0 at e,0 SUNW,fas sd st SUNW,hme SUNW,bpp

Probing /sbus@1f,0 at 0,0 cgsix

Probing /sbus@1f,0 at 1,0 SUNW,qfe SUNW,qfe SUNW,qfe SUNW,qfe


Sun Ultra 1 UPA/SBus (UltraSPARC 167MHz), No Keyboard

...


unknown console login: guest

Password:

Last login: Thu Jul 1 01:54:41 on console

Sun Microsystems Inc. SunOS 5.9 Generic May 2002..


> /usr/platform/sun4u/sbin/prtdiag -v

System Configuration: Sun Microsystems sun4u Sun Ultra 1 UPA/SBus (UltraSPARC 167MHz)

System clock frequency: 84 MHz

Memory size: 320 Megabytes


========================= CPUs =========================


Run Ecache CPU CPU

Brd CPU Module MHz MB Impl. Mask

--- --- ------- ----- ------ ------ ----

0 0 0 167 0.5 US-I 2.2


========================= IO Cards =========================


Bus Freq

Brd Type MHz Slot Name Model

--- ---- ---- ---------- ---------------------------- --------------------

0 SBus 25 0 cgsix SUNW,501-2325

0 SBus 25 1 SUNW,qfe SUNW,sbus-qfe

0 SBus 25 1 SUNW,qfe SUNW,sbus-qfe

0 SBus 25 1 SUNW,qfe SUNW,sbus-qfe

0 SBus 25 1 SUNW,qfe SUNW,sbus-qfe

0 SBus 25 14 SUNW,fas/sd (block)

0 SBus 25 14 SUNW,hme

0 SBus 25 14 SUNW,bpp

ERROR: Cannot determine PCI device type.


No failures found in System

===========================


========================= HW Revisions =========================


ASIC Revisions:

---------------

SBus: sbus Rev 1

FEPS: SUNW,hme Rev 22


System PROM revisions:

----------------------

OBP 3.25.0 1999/12/03 11:38 POST 3.11.4 1997/05/27 02:26


Consegna & pagamento


Consegna
Ritiro da parte dell'acquirente a 8803 Rüschlikon, CHF 0.00
Metodo di pagamento
Pagamento in contanti al ritiro

Cronologia delle offerte ( 0 )


Al momento non c'è ancora nessuna offerta.

Informazioni aggiuntive


Numero dell'articolo
1336592556

Articoli simili

Valuta questi risultati